ZPTG001 Connection module for light curtains

Available from stock

Optical Data

Switching Hysteresis 15 %

Electrical Data

Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 10 mA
Switching Frequency 555 Hz
Response Time 900 µs
Temperature Drift < 10 %
Temperature Range -25 ... 60 °C
Switching Output Voltage Drop < 2 V
Switching Output/Switching Current 100 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link
Protection Class III

Mechanical Data

Setting Method IO-Link
Housing Material Brass, nickel-plated
Connection M8 × 1; 4-pin
Weight 65 g

General Data

Scope of delivery 1 × ZPTG003 end cap
1 × connection module
Packaging unit 1 Piece

Output

IO-Link yes
PNP NO yes

Adjustable parameters

Output NPN
PNP
Push-pull
Circuit NC
NO

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Connection Diagram