text.skipToContent text.skipToNavigation

P1NH701 Reflex Sensor with Background Suppression

Available from stock
The reflex sensor with background suppression works with laser light according to the angle measurement principle and is designed to detect objects against any background. The sensor always has the same switching distance, regardless of the color, shape and surface of the objects. Thanks to the fine laser beam, even small parts can be reliably detected. The IO-Link interface can be used to configure reflex sensors (PNP/NPN, NC/NO) and to output switching statuses.

Optical Data

Range 300 mm
Setting Range 65 ... 300 mm
Switching Hysteresis  < 1 %
Light Source Laser (red)
Wavelength 655 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 10,000 Lux
Light Spot Diameter see Table 1

Electrical Data

Supply Voltage 10 ... 30 V DC
Supply Voltage with IO-Link 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 15 mA
Switching Frequency 1,000 Hz
Switching Frequency (interference-free mode) 500 Hz
Response time (interference-free mode) 1 ms
Response Time 0.5 ms
Temperature Drift < 2 %
Temperature Range -25 ... 60 °C
Switching Output Voltage Drop < 2 V
Switching Output/Switching Current 100 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.1
Protection Class III

Mechanical Data

Setting Method Single-turn
Housing Material Plastic, ABS/PC
Degree of Protection IP67/IP68
Connection M12 × 1; 4-pin
Optic Cover Plastic, PMMA
Weight 29 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 2,096.76 a

Output

PNP NC, PNP NO yes
IO-Link yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit NC
NO
inactive
Error output
NC+NO
Other parameters Off-delay
On-delay
Mode of operation
Hysteresis
Switching point
Emitted light
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Table 1

Detection Range 65 mm 150 mm 300 mm
Light Spot Diameter 3 mm 2,5 mm 1,5 mm

Connection Diagram

Switching Distance Deviation

Typical characteristic curve based on white, 90 % remission
Sr = Switching Distance
dSr = Switching Distance Change
black 6 % remission
grey 18 % remission

Ctrl. Panel

05 = Switching Distance Adjuster
30 = Switching Status/Contamination Warning
68 = supply voltage indicator

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode Screw M4 = 0.5 Nm

Complementary Products

  • Dust Extraction Tube STAUBTUBUS-03
  • IO-Link Master
  • Set Protective Housing Z1NS001
  • Software
Initial start-up instructions
Operating instructions
Product description file
Product description file
IODD_P1NH701_V1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_P1NHxxx_mech.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
P1NE_P1NH_P1NK_P1NL_IO-Link_V1.1_Manufacturer_declaration.pdf

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison