Optical Data

Range 30mm
Switching Hysteresis  < 15%
Light Source Infrared Light
Service Life (T = +25 °C) 100,000h
Max. Ambient Light 10,000Lux
Opening Angle 12°

Electrical Data

Supply Voltage 10 ... 30V DC
Current Consumption (Ub = 24 V) < 40mA
Switching Frequency 1,500Hz
Response Time 330µs
Temperature Drift < 10%
Temperature Range -25 ... 60°C
Switching Output Voltage Drop < 2.5V
PNP Switching Output/Switching Current 200mA
Residual Current Switching Output < 50µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Protection Class III

Mechanical Data

Housing Material Brass, nickel-plated
Full Encapsulation yes
Degree of Protection IP67
Connection Cable; 4-wire
Cable length (L) 2m
Cable Jacket Material Plastic, PVC
Wire cross-section 0.5mm²
Weight 183g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 2,337.8a

General Data

Scope of delivery 1 × initial start-up instructions
1 × MUTTER-M18-E001 hex nut
1 × sensor

Output

PNP NC, PNP NO yes

Adjustable parameters

Circuit NC
NC+NO
NO
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Connection Diagram

Switching Distance Deviation

Typical characteristic curve based on white, 90 % remission
Sr = Switching Distance
dSr = Switching Distance Change
black 6 % remission
grey 18 % remission

Ctrl. Panel

30 = Switching Status/Contamination Warning
05 = Switching Distance Adjuster

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode B_SYM_SCHLUESSEL_24.pdf Wrench Size