text.skipToContent text.skipToNavigation

HD03PA Reflex Sensor Energetic

Available from stock
Thanks to fine focusing optics the background is suppressed beyond 50 mm.

Optical Data

Range 30 mm
Switching Hysteresis  < 15 %
Light Source Infrared Light
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux
Opening Angle 12 °

Electrical Data

Supply Voltage 10 ... 30 V DC
Current Consumption (Ub = 24 V) < 40 mA
Switching Frequency 1,500 Hz
Response Time 330 µs
Temperature Drift < 10 %
Temperature Range -25 ... 60 °C
Switching Output Voltage Drop < 2.5 V
PNP Switching Output/Switching Current 200 mA
Residual Current Switching Output < 50 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Protection Class III

Mechanical Data

Housing Material Brass, nickel-plated
Full Encapsulation yes
Degree of Protection IP67
Connection Cable, 4-wire, 2 m
Cable Jacket Material Plastic, PVC
Weight 183 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 2,337.8 a

Output

PNP NC, PNP NO yes

Adjustable parameters

Circuit NC
NC+NO
NO
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Connection Diagram

Switching Distance Deviation

Typical characteristic curve based on white, 90 % remission
Sr = Switching Distance
dSr = Switching Distance Change
black 6 % remission
grey 18 % remission

Ctrl. Panel

30 = Switching Status/Contamination Warning
05 = Switching Distance Adjuster

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode B_SYM_SCHLUESSEL_24.pdf Wrench Size