text.skipToContent text.skipToNavigation

YP11MGV-P24 Laser Distance Sensor Triangulation

Available from stock
These sensors can measure distances and display analog output. Their high resolution and wide variety of measuring ranges allow them to be used in innumerable applications. The output signal is practically independent of the object's color.

Optical Data

Working Range 50 ... 100 mm
Measuring Distance 75 mm
Measuring Range 50 mm
Resolution 100 µm
Linearity 0.5 %
Linearity Deviation 250 µm
Light Source Laser (red)
Wavelength 660 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 2
Max. Ambient Light 10,000 Lux
Light Spot Diameter 1 mm

Electrical Data

Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 30 mA
Cut-Off Frequency 1 kHz
Response Time 500 µs
Temperature Drift 20 µm/K
Temperature Drift (+10…40 °C) 10 µm/K
Temperature Range -10 ... 60 °C
Error Output Voltage Drop < 2.5 V
PNP Error Output/Switching Current 200 mA
Analog Output 0...10 V
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Protection Class III

Mechanical Data

Housing Material Plastic, PBT
Optic Cover Glass
Full Encapsulation yes
Degree of Protection IP67
Connection Cable; 6-wire
Cable length (L) 6 m
Wire cross-section 0.25 mm²
Weight 397 g

General Data

Scope of delivery 1 × initial start-up instructions
1 × laser warning sign
1 × sensor

Output

Error Output yes
Analog Output yes

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Connection Diagram

Error of Measurement

Typical characteristic curve based on white, 90 % remission
Sr = Switching Distance
dSr = Switching Distance Change
black 6 % remission
Aluminum

Ctrl. Panel

03 = Error Indicator
12 = Analog Output Indicator

Complementary Products

  • Analog Evaluation Unit AW02
  • IO-Link converter
Initial start-up instructions
Operating instructions
Declarations of Conformity / Approvals
Product Comparison