text.skipToContent text.skipToNavigation

OTII802C0103 Reflex Sensor Energetic

Available on request.
The photoelectronic sensors in the hygienic housing are distinguished by a captive optic cover and food-safe, FDA-compliant materials. The hygienic design with no corners or edges enables optimal flow of cleaning agents. The laser-welded 316L stainless steel housing (1.4404/V4A) is resistant to high-pressure cleaning (degree of protection IP69K) and suitable for cleaning-intensive applications. When combined with the available accessories, gap-free installation is guaranteed for the highest hygiene requirements. Setting is performed by means of touch teach-in through the hermetically sealed housing.

Optical Data

Range 800 mm
Switching Hysteresis  < 15 %
Light Source Infrared Light
Wavelength 880 nm
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux

Electrical Data

Supply Voltage 10 ... 30 V DC
Current Consumption (Ub = 24 V) < 40 mA
Switching Frequency 1,600 Hz
Response Time 313 µs
On-/Off-Delay (RS-232) 0 ... 5 s
Temperature Drift < 5 %
Temperature Range -25 ... 60 °C
Switching Output Voltage Drop < 2.5 V
PNP Switching Output/Switching Current 200 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Lockable yes
Teach Mode NT, MT
Protection Class III

Mechanical Data

Setting Method Teach-In
Housing Material Stainless steel, V4A (1.4404 / 316L)
Degree of Protection IP68/IP69K
Connection M12 × 1; 4-pin
Optic Cover Plastic, PMMA (FDA)
Material Control Panel Plastic, PC (FDA)
Ecolab yes
Weight 132 g

Output

PNP NO yes
RS-232 with Adapterbox yes

Adjustable parameters

Circuit NC
NC/NO
NO
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Table 1

Detection Range 100 mm 500 mm 800 mm
Light Spot Diameter 19 mm 40 mm 55 mm

Connection Diagram

Ctrl. Panel

06 = Teach Button
01 = Switching Status Indicator
02 = Contamination Warning

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Emitter 2 = Receiver

Examples of Installation

Complementary Products

  • Adapterbox A232
  • PNP-NPN Converter BG2V1P-N-2M
  • Software
Initial start-up instructions
Operating instructions
Interface protocol
Interface protocol
Interface_Protocol_diverse_Types.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
InoxSens_Products_FDA_Conformity.pdf OxII_Ecolab.pdf
Product Comparison