text.skipToContent text.skipToNavigation

OY1P303P0102 Laser Distance Sensor Time of Flight

Available from stock
These sensors have scratch-resistant optics and the emitted light can be switched off. They use the transit time measurement principle to measure the distance between the sensor and the object. wenglor interference-free technology (wintec) has revolutionized sensor technology: It makes it possible to mount several sensors directly next to, or opposite each other without the sensors influencing each other. The sensors reach a very high switching frequency and use laser class 1, which is safe for the human eye.

Optical Data

Working Range 50 ... 3,050 mm
Measuring Range 3,000 mm
Reproducibility maximum 1 mm
Linearity Deviation (200…3050 mm) 7 mm
Linearity Deviation (50…200 mm) 15 mm
Switching Hysteresis 3 ... 20 mm
Light Source Laser (red)
Wavelength 660 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 10,000 Lux
Beam Divergence < 2 mrad

Electrical Data

Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 70 mA
Switching Frequency 250 Hz
Measuring Rate 1 ... 500 /s
On-/Off-Delay 0 ... 10,000 ms
Temperature Drift < 0.4 mm/K
Temperature Range -40 ... 50 °C
Number of Switching Outputs 2
Switching Output Voltage Drop < 2.5 V
Switching Output/Switching Current 100 mA
Analog Output 4...20 mA
Short Circuit Protection yes
Reverse Polarity and Overload Protection yes
Teach Mode HT, VT, FT, TP
Interface IO-Link V1.1
Protection Class III

Mechanical Data

Setting Method Menu (OLED)
Housing Material Plastic, ABS
Plastic, PC
Optic Cover Plastic, PMMA
Degree of Protection IP68
Connection M12 × 1; 4-pin
Weight 43 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 349.73 a

Output

Error Output yes
Analog Output yes
IO-Link yes

Adjustable parameters

Analog output 0...10 V
4...20 mA
Output Analog Output
Error Output
Push-pull
NPN
PNP
Contamination Output
Other parameters Off-delay
Scale analog output
On-delay
Filter
Hysteresis
Emitted light
Teach mode
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
Display brightness may decrease with age. This does not result in any impairment of the sensor function.

Table 1

Working Distance 0 m 3 m
Light Spot Diameter 5 mm 9 mm

Connection Diagram

Switching Distance Deviation

Typical characteristic curve based on white, 90 % remission
Sr = Switching Distance
dSr = Switching Distance Change
black 6 % remission
grey 18 % remission
Aluminum

Ctrl. Panel

20 = Enter key
22 = Up key
23 = Down key
60 = display

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode Screw M4 = 0.5 Nm

Complementary Products

  • IO-Link Master
  • Set Protective Housing ZSP-NN-02
  • Protective Housing ZSV-0x-01
  • Analog Evaluation Unit AW02
  • Software
Initial start-up instructions
Operating instructions
Quick-start guide
Product description file
Product description file
IODD_OY1P303P0102_V1.1.zip IODD_OY1P303P0102_V1.0.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_OY1P303P0102.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
OY1P303P0102_IO-Link_V1.1_Manufacturer_declaration.pdf