text.skipToContent text.skipToNavigation

OPT104 Reflex Sensor with Background Suppression

These sensors have been specially designed for use in accumulation roller conveyors. Their compact design allows for installation between two rollers below the conveyor level. They are thus protected against mechanical damage.

Optical Data

Range 550 mm
Potentiometer min 220 ... 270 mm
Potentiometer center 320 ... 400 mm
Potentiometer max 550 ... 630 mm
Switching Hysteresis 15 %
Light Source Infrared Light
Wavelength 880 nm
Service Life (T = +25 °C) 100,000 h
Risk Group (EN 62471) 1
Max. Ambient Light 10,000 Lux
Opening Angle 5 °

Electrical Data

Supply Voltage 18 ... 30 V DC
Current Consumption Sensor (Ub = 24 V) < 30 mA
Switching Frequency 100 Hz
Response Time 5 ms
Temperature Drift < 10 %
Temperature Range -15 ... 50 °C
Number of Switching Outputs 1
Switching Output Voltage Drop < 0.8 V
PNP Switching Output/Switching Current 200 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Logic yes
Single Discharge yes
Block Forwarding yes
Solenoid Valve yes
Protection Class III

Mechanical Data

Setting Method Potentiometer
Housing Material Plastic
Full Encapsulation yes
Degree of Protection IP65
Connection M12 × 1; 4-pin
Cable length (L) 880 mm
Weight 236 g

General Data

Scope of delivery 1 × sensor

Pneumatic Solenoid Valve Unit

Valve no. K04
Supply Voltage Valve 19.2 ... 28.8 V
Current Consumption Valve 86 mA
Operating Pressure 4 ... 7 bar
Nominal Width 0.8 mm
Nominal flow rate 1 -> 2 20 NL/min
Nominal flow rate 2 -> 3 100 NL/min
Supply-Line Connector Pipe 2× 8×1
Working-Line Connector Pipe 4×1
Valve function 3/2-Way
Switching function NC

Output

PNP NC yes

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Connection Diagram

Switching Distance Deviation

Typical characteristic curve based on white, 90 % remission
Pot. = Potentiometer Setting
dSr = Switching Distance Change
black 6 % remission
grey 18 % remission

Ctrl. Panel

30 = Switching Status/Contamination Warning
05 = Switching Distance Adjuster

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode
Initial start-up instructions
Operating instructions
Declarations of Conformity / Approvals
Notice of Discontinuation