The photoelectronic sensors in the hygienic housing are distinguished by a captive optic cover and food-safe, FDA-compliant materials. The hygienic design with no corners or edges enables optimal flow of cleaning agents. The laser-welded 316L stainless steel housing (1.4404/V4A) is resistant to high-pressure cleaning (degree of protection IP69K) and suitable for cleaning-intensive applications. When combined with the available accessories, gap-free installation is guaranteed for the highest hygiene requirements. Setting is performed by means of touch teach-in through the hermetically sealed housing.

Optical Data

Range 100 mm
Setting Range 10 ... 100 mm
Switching Hysteresis  < 5 %
Light Source Red Light
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux

Electrical Data

Supply Voltage 10 ... 30 V DC
Current Consumption (Ub = 24 V) < 30 mA
Switching Frequency 600 Hz
Response Time 800 µs
Temperature Drift < 10 %
Temperature Range -25 ... 60 °C
Switching Output Voltage Drop < 2.5 V
PNP Switching Output/Switching Current 200 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Lockable yes
Teach Mode HT, VT
Protection Class III

Mechanical Data

Setting Method Teach-In
Housing Material Stainless steel, V4A (1.4404 / 316L)
Degree of Protection IP68/IP69K
Connection M12 × 1; 4-pin
Optic Cover Plastic, PMMA (FDA)
Material Control Panel Plastic, PC (FDA)
Ecolab yes
Weight 98 g

Output

PNP NO yes
RS-232 with Adapterbox yes

Adjustable parameters

Circuit NC
NC/NO
NO
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Table 1

Detection Range 10 mm 40 mm 100 mm
Light Spot Diameter 2,5 × 7 mm 2,5 × 5 mm 2,5 × 2,5 mm

Connection Diagram

Switching Distance Deviation

Typical characteristic curve based on white, 90 % remission
Sr = Switching Distance
dSr = Switching Distance Change
black 6 % remission
grey 18 % remission

Ctrl. Panel

06 = Teach Button
02 = Contamination Warning
01 = Switching Status Indicator

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Emitter 2 = Receiver

Examples of Installation

Complementary Products

  • Adapterbox A232
  • PNP-NPN Converter BG2V1P-N-2M
  • Software
Initial start-up instructions
Operating instructions
Interface protocol
Interface protocol
Interface_Protocol_HGA.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
InoxSens_Products_FDA_Conformity.pdf OxII_Ecolab.pdf
Product Comparison