text.skipToContent text.skipToNavigation

HT60MGV80 Reflex Sensor with Background Suppression

Available from stock
These sensors are equipped with an analog output, as well as a digital output. The upper and lower switching points of the digital output can be adjusted with two potentiometers. The digital output is activated when an object is located within the window defined in this way.
This product has been discontinued, but is still available as a spare part.

Optical Data

Working Range 300 ... 600mm
Measuring Distance 450mm
Measuring Range 300mm
Resolution see Table 1
Linearity 1%
Switching Hysteresis 20mm
Light Source Red Light
Wavelength 660nm
Service Life (T = +25 °C) 100,000h
Max. Ambient Light 10,000Lux
Light Spot Diameter see Table 1

Electrical Data

Supply Voltage 18 ... 30V DC
Current Consumption (Ub = 24 V) < 50mA
Cut-Off Frequency 50Hz
Response Time 10ms
Temperature Drift 100µm/K
Temperature Range -10 ... 60°C
Switching Output Voltage Drop < 2.5V
PNP Switching Output/Switching Current 200mA
Error Output Voltage Drop < 2.5V
PNP Error Output/Switching Current 200mA
Analog Output 0...10 V
Output Current Analog Output 500µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Protection Class III

Mechanical Data

Housing Material Plastic, PBT
Degree of Protection IP67
Connection M12 × 1; 8-pin
Weight 191g

General Data

Scope of delivery 1 × BEF-SET-03 mounting set
1 × initial start-up instructions
1 × sensor

Output

Error Output yes
PNP NO yes
Analog Output yes

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Table 1

Working Distance 300 mm 450 mm 600 mm
Light Spot Diameter 10 mm 15 mm 20 mm
Resolution 0,3 mm 2 mm 5 mm

Connection Diagram

Error of Measurement

Typical characteristic curve based on white, 90 % remission
S = Measuring Distance
dS = Deviation
black 6 % remission
grey 18 % remission

Ctrl. Panel

01 = Switching Status Indicator
13 = Upper Potentiometer
14 = Lower Potentiometer
33 = Analog Voltage Output-/Error Warning

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Receiver Diode 2 = Transmitter Diode 3 = Receiver Diode Screw M4 = 1 Nm

Complementary Products

  • Analog Evaluation Unit AW02
  • IO-Link converter
Initial start-up instructions
Operating instructions
Declarations of Conformity / Approvals
Notice of Discontinuation
Product Comparison