text.skipToContent text.skipToNavigation

SS2-00VA000R3 Safety Analysis Module for Safety Through-Beam Sensor

The individual safety light barrier control unit is used to monitor up to 4 through-beam sensors. Interruption of any single beam results in deactivation of the safety output.

Electrical Data

Supply Voltage 24 V DC
Current Consumption (Ub = 24 V) < 260 mA
Response Time < 30 ms
Temperature Range 0 ... 55 °C
Safety Output Relay
Number of safety outputs (OSSDs) 2
Switching Output Voltage Drop < 3 V
PNP Switching Output/Switching Current < 100 mA
Relay Output/Switching Current (250 VAC) 2 A
Reverse Polarity Protection yes
Protection Class II

Mechanical Data

Housing Material Plastic, PA
Degree of Protection IP20
Connection Screw Clamp
Weight 247 g

Safety-relevant Data

Safety Category (EN ISO 13849-1) 2
Performance Level (EN ISO 13849-1) PL c
PFHD 3,16 × E-7 1/h *
Safety Integrity Level (EN 62061) SILCL1

Function

Restart Inhibit yes
Contactor Monitoring yes
Muting Mode yes
Override yes

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* PFHD for control incl. 4 SL2

Connection Table

B_ANS_TAB_37.pdf

Safety Key Figure T10d

Ctrl. Panel

71 = Channel 1
72 = Channel 2/Error Indicator
73 = OSSD/Diagnosis
54 = Muting
74 = Muting Sensor 1
75 = Muting Sensor 2

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")

Complementary Products

  • Through-Beam Sensor SL2-00NS000H2/SL2-00NE000H2
  • Muting Indicator SM0-00CA000C1
  • Muting Sensor: PNP NC, NO antivalent
  • Software
Operating instructions
Quick-start guide
Declarations of Conformity / Approvals
Product certificates
Product certificates
SS2-00VA000Rx_TUEV_Certificate.pdf
Product Comparison