This color sensor is capable of evaluating up to three colors simultaneously. A small spot and a large working range are made possible thanks to single-lens optics. All sensor settings can be selected by means of teach-in, as well as via the RS-232 interface. Values generated by the sensor can be read out via the interface or digital switching outputs. The sensor has 3 switching outputs and supplies RGB, XYZ and HSL color values via the interface.
This product has been discontinued, but is still available as a spare part.

Optical Data

Working Range 30 ... 40 mm
Working Distance 35 mm
Light Source LED, white
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux
Light Spot Diameter 3 mm

Electrical Data

Supply Voltage 10 ... 30 V DC
Current Consumption (Ub = 24 V) < 80 mA
Switching Frequency 1.8 kHz
Response time ~ 1.8/1,000 μs × filter
Temperature Range -25 ... 60 °C
Number of Switching Outputs 3
Switching Output Voltage Drop 1.5 V
PNP Switching Output/Switching Current 100 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Teach Mode FT
Interface RS-232
Number of Digital Inputs 2
Protection Class III

Mechanical Data

Setting Method Menu (OLED)
Housing Material Plastic, ABS
Plastic, PC
Optic Cover Plastic, PMMA
Degree of Protection IP68
Connection M12 × 1; 8-pin
Weight 44 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 425.77 a

General Data

Scope of delivery 1 × BEF-SET-44 mounting set
1 × initial start-up instructions
1 × sensor

Output

RS-232 Interface yes
Error Output yes
Contamination Output yes
Push-Pull yes
NO yes
External teach-in input yes

Adjustable parameters

Output Error Output
Push-pull
NPN
PNP
Contamination Output
Circuit NC
NC/NO
NO
Other parameters Teach-in mode
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
Display brightness may decrease with age. This does not result in any impairment of the sensor function.

Connection Diagram

Ctrl. Panel

20 = Enter key
22 = Up key
23 = Down key
60 = display

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
Screw M4 = 0.5 Nm

Complementary Products

  • Interface Cable S232W3
  • Protective Housing ZSV-0x-01
  • Set Protective Housing ZSP-NN-02
  • Fieldbus Gateway ZAGxxxN01, EPGG001
  • Software
  • Dust extraction tube
Initial start-up instructions
Operating instructions
Quick-start guide
General instructions
General instructions
Instructions_for_replacing_FP04PCT80_with_OFP401P0189.pdf
Interface protocol
Interface protocol
Interface_Protocol_OFP401P0189.pdf
Declarations of Conformity / Approvals
Notice of Discontinuation
Product Comparison