text.skipToContent text.skipToNavigation

OLDK503A0002 Retro-Reflex Sensor Universal

Available from stock
A reflector must be used in combination with these sensors. They can be installed in all kinds of industrial environments thanks to ample functional reserve. Even reflective objects can be reliably recognized through the use of polarized light.

Optical Data

Range 5,000 mm
Reference Reflector/Reflector Foil RQ100BA
Switching Hysteresis  < 15 %
Light Source Red Light
Polarization Filter yes
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux
Opening Angle 5 °
Light Spot Diameter see Table 1
Two-Lens Optic yes

Electrical Data

Supply Voltage 10 ... 30 V DC
Supply Voltage with IO-Link 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 30 mA
Switching Frequency 700 Hz
Switching frequency (speed mode) 900 Hz
Response Time 0.7 ms
Response time (speed mode) 0.6 ms
Temperature Drift < 10 %
Temperature Range -25 ... 60 °C
Switching Output Voltage Drop < 2.5 V
PNP Switching Output/Switching Current 200 mA
Residual Current Switching Output < 50 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Lockable yes
Interface IO-Link V1.1
Protection Class III

Mechanical Data

Setting Method Potentiometer
Housing Material Plastic, ABS/GF
Degree of Protection IP67
Connection M12 × 1; 4-pin
Weight 17 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 2,953.75 a

General Data

Scope of delivery 1 × Z0008 mounting console
1 × initial start-up instructions
1 × MUTTER-M8-E002 hex nut
1 × sensor
Packaging unit 1 Piece

Output

IO-Link yes
PNP NC, PNP NO yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit NC
NC+NO
NO
Other parameters Off-delay
On-delay
Mode of operation
Error output
Switching hysteresis
Emitted light
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
*IO-Link availability is valid for all sensors from revision G. The revision can be found in the production order number “xxxxx/G/xxxxxx,” which is indicated on the product label.

Table 1

Working Distance 0,2 m 0,5 m 5 m
Light Spot Diameter 17 mm 35 mm 330 mm

Connection Diagram

Ctrl. Panel

05 = Switching Distance Adjuster
30 = Switching Status/Contamination Warning
68 = Power LED

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode B_SYM_SCHLUESSEL_24.pdf Wrench Size

Reflector data

RQ100BA 0.01 ... 5 m
RE18040BA 0.01 ... 4.5 m
RQ84BA 0.01 ... 4.5 m
RR84BA 0.01 ... 4.5 m
RE9538BA 0.01 ... 2.2 m
RE6151BM 0.01 ... 4.3 m
RR50_A 0.01 ... 3.5 m
RE6040BA 0.01 ... 4 m
RE8222BA 0.01 ... 2.6 m
RR34_M 0.01 ... 2.5 m
RE3220BM 0.01 ... 1.5 m
RE6210BM 0.01 ... 1 m
RR25_M 0.01 ... 1.3 m
RR25KP 0.04 ... 0.8 m
RR21_M 0.01 ... 1.1 m
ZRAE02B01 0.01 ... 2.2 m
ZRDS01R01 0.05 ... 0.8 m
ZRME01B01 0.01 ... 0.5 m
ZRME03B01 0.01 ... 2.5 m
ZRMR02K01 0.01 ... 0.7 m
ZRMS02_01 0.01 ... 1 m
RF505 0.05 ... 1.5 m
RF255 0.05 ... 1.1 m
RF508 0.05 ... 1.5 m
RF258 0.05 ... 1.1 m
RF4050 0.05 ... 1 m
ZRAF07K01 0.05 ... 1.1 m
ZRAF08K01 0.05 ... 1.5 m
ZRDF03K01 0.04 ... 3.4 m
ZRDF10K01 0.04 ... 4.5 m

Complementary Products

  • IO-Link Master
  • Reflector, Reflector Foil
  • Software
  • Dust Extraction Tube STAUBTUBUS-01
Initial start-up instructions
Operating instructions
Product description file
Product description file
wenglor-OLDK503A0002-20231215-IODD1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_OLDK503x00xx.pdf
Declarations of Conformity / Approvals
Product Comparison