text.skipToContent text.skipToNavigation

OEEI152U0135 Light Curtain for Measuring Tasks

Available from stock
As these light curtains for measurement task are equipped with an integrated evaluation unit, external connection units are not needed. Objects are both recognized (via the digital output) and measured (via the analog output). The light curtains can be set up easily using the menu-controlled graphic display. Convenient parametrization and quick diagnosis is possible via the IO-Link interface. The adequate mounting angle BEF-SET-33 is included in the delivery.

Optical Data

Range 2,000 mm
Measurement Field Height (MFH) 150 mm
Beam Distance 2 mm
Light Source Infrared Light
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux
Opening Angle 10 °

Electrical Data

Sensor Type Receiver
Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 60 mA
Switching Frequency 60 Hz
Response Time 8 ms
On-/Off-Delay 0 ... 10 s
Temperature Drift < 10 %
Temperature Range -25 ... 60 °C
Number of Switching Outputs 2
Switching Output Voltage Drop < 2.5 V
Switching Output/Switching Current 100 mA
Residual Current Switching Output < 50 µA
Analog Output 0...10 V
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Lockable yes
Interface IO-Link V1.0
Protection Class III

Mechanical Data

Setting Method Menu (OLED)
Housing Material Aluminum, powder-coated
Plastic, PA
Plastic, PBT
Optic Cover Plastic, PC
Degree of Protection IP65
Connection M12 × 1; 4/5-pin
Weight 465 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 147.29 a

Output

PNP NC yes
IO-Link yes

Adjustable parameters

Analog output 0...10 V
4...20 mA
Output Analog Output
Error Output
Push-pull
PNP
Circuit NC
NC/NO
NO
Other parameters Off-delay
On-delay
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
Display brightness may decrease with age. This does not result in any impairment of the sensor function.

Connection Diagram

Ctrl. Panel

20 = Enter key
22 = Up key
23 = Down key
60 = display

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")

Complementary Products

  • IO-Link Master
  • Analog Evaluation Unit AW02
  • Software
Initial start-up instructions
Operating instructions
Quick-start guide
Product description file
Product description file
IODD_OEEIxxxU0135_V1.0.1.zip
Declarations of Conformity / Approvals
Product certificates
Product certificates
OEEI_IO-Link_V1.0_Manufacturer_declaration.pdf
Product Comparison