P1PY138 Laser Distance Sensor Time of Flight

Available from stock
The sensors function in accordance with the principle of transit time measurement with laser class 1. The wintec with Dynamic Sensitivity technology (DS) enables previously unattainable reception sensitivity even with very weak signals. The versions with a large light spot are suitable for reliably detecting objects with stamped, perforated or very uneven surfaces. The wintec also works very reliably in adverse ambient conditions, such as those caused by ambient light or dirt. Extensive condition monitoring functions additionally enable predictive maintenance and trouble-free operation.

Optical Data

Working Range 0 ... 5,000 mm
Measuring Range 50 ... 5,000 mm
Reproducibility maximum 3 mm*
Linearity Deviation 10 mm*
Light Source Laser (red)
Wavelength 660 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Max. Ambient Light 100,000 Lux
Light Spot Diameter see Table 1
Reflector required no

Electrical Data

Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 40 mA
Measuring Rate 100 /s*
Measuring Rate (max.) 500 /s*
Temperature Drift < 0.4 mm/K
Temperature Range -40 ... 50 °C
Analog Output 4...20 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface IO-Link V1.1
Baud Rate COM3
Protection Class III
FDA Accession Number 2110079-001

Mechanical Data

Setting Method Teach-In
Housing Material Plastic, ABS
Optic Cover Plastic, PMMA
Degree of Protection IP67/IP68
Connection M12 × 1; 4/5-pin
Weight 41 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 512.61 a

Output

Error Output yes
Analog Output yes
IO-Link yes

Adjustable parameters

Output Error Output
Warning output
Other parameters Off-delay
On-delay
Sensitivity
Filter
Unit of measure
Measuring mode
Emitted light
Sensor localization
Key illumination
Teach mode
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* Depends on mode, see table 2

Table 1

Working Distance 0 m 2 m 5 m
Light Spot Diameter 5 mm 30 mm 65 mm

Table 2

Connection Diagram

- = supply voltage 0 V
+ = supply voltage +
E/A1 = programmable input/output / IO-Link
E3 = input
O = analog output

Ctrl. Panel

06 = Teach Button
68 = supply voltage indicator
5a = Switching Status Indicator, A1
63 = Analog Output Current Indicator

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode Screw M4 = 0.5 Nm

Complementary Products

  • IO-Link Master
  • Software
Initial start-up instructions
Operating instructions
Product description file
Product description file
IODD_P1PY138_V1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_PxPY10x.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates