weFlux² two-wire pressure sensors with analog output are distinguished by their space-saving design and a short response time of less than one millisecond, making them ideally suited for quick pressure measurement applications – for example when monitoring pressure curves in hydraulic systems. Thanks to the temperature element integrated in the measuring cell, the sensors with a G3/4" flush-mounted process connection are equipped with accurate temperature compensation.

Sensor-specific data

Measuring Range 0 ... 0.25 bar
Measurement Type relative
Maximum overload pressure 1 bar
Bursting pressure 1.5 bar
Medium Liquids, gases
Pressure response time (t90) < 1 ms
Measuring error (total)  ± 0.5 %
Hysteresis  < ± 0.1 %
Linearity Deviation  < ± 0.5 %
Zero-point error < ± 0.1 %
Repeat Accuracy < ± 0.1 %
Temperature coefficient zero-point <± 0,05% /10K
Temperature coefficient range <± 0,05% /10K

Environmental conditions

Temperature of medium -25 ... 125 °C**
Ambient temperature -25 ... 80 °C
Storage temperature -25 ... 80 °C
EMC DIN EN 61326-2-3
Shock resistance per DIN IEC 68-2-27 50 g / 11 ms
Vibration resistance per DIN IEC 60068-2-6 10 g (10...2000 Hz)

Electrical Data

Supply Voltage 12 ... 32 V DC
Current Consumption (Ub = 24 V) < 21 mA
Number of analog outputs 1
Analog Output 4...20 mA
Signal source Pressure
Current Output Load Resistance < 500 Ohm
Short Circuit Protection yes
Reverse Polarity Protection yes
Protection Class III

Mechanical Data

Sensor element Ceramic membrane
Housing Material Stainless steel, V4A (1.4404/316L)
Material in contact with media Stainless steel, V4A (1.4404 / 316L)
Rubber, FKM
Ceramic
Degree of Protection IP65 *
Connection M12 × 1; 4-pin
Process Connection G3/4"; front
Seal material Fluororubber, FKM
Weight 264 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 3,283.16 a

Output

Analog Output yes

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* Not UL certified ** Sensors up to 125 °C medium temperature suitable. During installation, please ensure that the sensor housing is sufficiently cooled by the surroundings.

Connection Diagram

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
B_SYM_SCHLUESSEL_27.pdf Wrench Size
Initial start-up instructions
Quick-start guide
Declarations of Conformity / Approvals

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.