text.skipToContent text.skipToNavigation

FX9P002 Pressure Sensor with IO-Link

Available from stock
weFlux² pressure sensors precisely measure the relative pressure of any desired media. Depending on application requirements, either two switching outputs or one switching output and one analog output can be selected to output measured values. Furthermore, weFlux² pressure sensors offer new dimensions in individual parameter configurability. Sensor parameters, filter and output functions as well as the unit of measurement of the measured values (bar, PSI or Pascal) can be adjusted as needed.

Sensor-specific data

Measuring Range 0 ... 250 bar
Measurement Type relative
Maximum overload pressure 500 bar
Bursting pressure 750 bar
Medium Liquids, gases
Pressure response time (t90) < 10 ms
Measuring error (total)  ± 1 %

Environmental conditions

Temperature of medium -25 ... 125 °C**
Ambient temperature -25 ... 80 °C
Atmospheric humidity 100% r.h.
Storage temperature -25 ... 80 °C
EMC DIN EN 61326-2-3
Shock resistance per DIN IEC 68-2-27 50 g / 11 ms
Vibration resistance per DIN IEC 60068-2-6 10 g (10...2000 Hz)

Electrical Data

Supply Voltage 12 ... 32 V DC
Current Consumption (Ub = 24 V) < 15 mA
Number of Switching Outputs 2
Switching Output/Switching Current 100 mA
Switching Output Voltage Drop < 1.5 V
Number of analog outputs 1
Analog Output 4...20 mA
Signal source Pressure
Current Output Load Resistance < 500 Ohm
Voltage output load resistance > 1 kOhm
Interface IO-Link V1.1
Short Circuit Protection yes
Reverse Polarity Protection yes
Protection Class III

Mechanical Data

Setting Method IO-Link
Sensor element Stainless steel membrane
Housing Material Stainless steel, V4A (1.4404/316L)
Material in contact with media Stainless steel, V4A (1.4404 / 316L)
Stainless steel, V4A (1.4548/630)
Rubber, FKM
Degree of Protection IP68/IP69K *
Connection M12 × 1; 4-pin
Process Connection G 1/2"
Seal material Fluororubber, FKM
Weight 273 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 1,157.11 a

Output

Analog Output yes
PNP NO yes
IO-Link yes

Adjustable parameters

Analog output 0...10 V
4...20 mA
Output Analog Output
Push-pull
NPN
PNP
Circuit NC
NC/NO
NO
Other parameters 2 switching points
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* Not UL certified ** Sensors up to 125 °C medium temperature suitable. During installation, please ensure that the sensor housing is sufficiently cooled by the surroundings.

Connection Diagram

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
B_SYM_SCHLUESSEL_27.pdf Wrench Size
Initial start-up instructions
Operating instructions
Quick-start guide
Product description file
Product description file
IODD_FX9P_V1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_FXxPxxx.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
FXxP0_FXxQ0_IO-Link_V1.1_Manufacturer_declaration.pdf

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison