text.skipToContent text.skipToNavigation

FXSL004 Fill-level Sensor with IO-Link

Available from stock
LevelTech level sensors use innovative frequency-stroke technology to identify different media based on their resonance frequency. With two individually adjustable switching outputs, they enable reliable differentiation between foam and liquids or between two different media. For applications with frequently changing media, the adaptive trigger offers an efficient solution. The parameterization of the sensors, including filter and output functions, takes place flexibly via IO-Link. The robust, FDA-compliant stainless steel housing is easy to install even in confined spaces thanks to its compact format.

Sensor-specific data

Measuring principle Frequency sweep
Measuring Range > DK*** 1.5
Medium Liquids, granulate, powder
Response Time 0.04 s

Environmental conditions

Media temperature TM (TU < 50 °C) -40 ... 115 °C**
Media temperature TM brief (TU < 50 °C, t < 1 h) -40 ... 130 °C
Ambient temperature -40 ... 85 °C
Storage temperature -40 ... 85 °C
Pressure Resistance 100 bar

Electrical Data

Supply Voltage 8 ... 35 V DC
Current Consumption (Ub = 24 V) < 53 mA
Number of Switching Outputs 2
Power-up Time < 1.5 s
Switching Output/Switching Current 100 mA
Switching Output Voltage Drop ≤ 1.9 V
Signal source Change of medium
Leakage Current < 100 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Interface IO-Link V1.1

Mechanical Data

Setting Method IO-Link
Housing Material Stainless steel, V4A (1.4404/316L)
Material in contact with media Stainless steel, V4A (1.4404 / 316L)
Plastic, PEEK
Degree of Protection IP67
IP69K
Connection M12 × 1; 4-pin
Connector Plug Material Stainless Steel
Process Connection G 1/2"
Weight 69 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 633.2 a

General Data

Scope of delivery 1 × initial start-up instructions
1 × sensor

Output

Switchable to NC/NO yes
IO-Link yes
Push-Pull yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit NC
NC/NO
NO
Other parameters Adaptive trigger
Window trigger
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* mounted in closed metal tank
** TM= temperature of medium; TU= ambient temperature
*** The relative dielectric constant of the medium to be detected must be greater than 1.5. (DC = dielectric constant)

Connection Diagram

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")

Complementary Products

  • IO-Link Master
  • Software
Initial start-up instructions
Operating instructions
Product description file
Product description file
wenglor-LevelTech-20250917-IODD1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_FXSL004.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
Fluid_sensors_food_safety_declaration.pdf
Product Comparison