text.skipToContent text.skipToNavigation

P2KT001 Reflex Sensor Energetic

Available on request.
The reflex sensor works with red light according to the principle of energy and is designed to detect objects without a background. The switching distance is set for a given object. Note that: Bright objects reflect transmitted light better than dark objects. Dark (matte) objects can also be differentiated from bright (glossy) objects. This means that presence or stack height checks can be conducted or counting tasks carried out. The IO-Link interface can be used to configure reflex sensors (PNP/NPN, NC/NO, switching distance), as well as to output switching statuses and distance values. The robust V4A (1.4404/316L) stainless steel housing is resistant to oils and coolants, as well as cleaning agent.

Optical Data

Range 700 mm
Switching Hysteresis  < 10 %
Light Source Red Light
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux

Electrical Data

Supply Voltage 10 ... 30 V DC
Supply Voltage with IO-Link 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 20 mA
Switching Frequency 500 Hz
Switching frequency (speed mode) 1,000 Hz
Response Time 1 ms
Response time (speed mode) 0.5 ms
Temperature Drift < 10 %
Temperature Range -40 ... 60 °C
Switching Output Voltage Drop < 2 V
Switching Output/Switching Current 100 mA
Residual Current Switching Output < 50 µA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Lockable yes
Interface IO-Link V1.1
Protection Class III

Mechanical Data

Setting Method Potentiometer
Housing Material Stainless steel, V4A (1.4404 / 316L)
Degree of Protection IP68/IP69K
Connection M8 × 1; 4-pin
Optic Cover Plastic, PMMA
Ecolab yes
Weight 42 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 2,584.53 a

Output

IO-Link yes
PNP NC, PNP NO yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit inactive
Error output
NC
NC+NO
NO
Other parameters Off-delay
On-delay
Mode of operation
Hysteresis
Switching point
Emitted light
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Table 1

Detection Range 100 mm 300 mm 700 mm
Light Spot Diameter 20 mm 40 mm 80 mm

Connection Diagram

Ctrl. Panel

30 = Switching Status/Contamination Warning
05 = Switching Distance Adjuster
68 = supply voltage indicator

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode Screw M3 = 0,5 Nm
M8 × 1 plug without snap lock

Complementary Products

  • Software
  • IO-Link Master
Initial start-up instructions
Operating instructions
Product description file
Product description file
IODD_P2KT001.V1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_P2KTxxx.pdf
Declarations of Conformity / Approvals
Product certificates
Product certificates
P2KXxxx_Ecolab.pdf P2K_IO-Link_V1.1_Manufacturer_declaration.pdf

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison