text.skipToContent text.skipToNavigation

FM6P201 Pressure Sensor

Available on request.
The weFlux²micro miniature pressure sensor with analog output is distinguished by its space-saving design and low weight. This enables precise pressure measurements in confined installation spaces and on moving plant components such as robot arms. The short response time (<1 ms) allows the sensor to be implemented in quick pressure measurement applications – for example, when monitoring pressure curves in hydraulic systems.

Sensor-specific data

Measuring Range -1 ... 25 bar
Measurement Type relative
Maximum overload pressure 50 bar
Bursting pressure 120 bar
Medium Liquids;** gases
Pressure response time (t90) < 1 ms
Measuring error (total)  ± 1 %
Hysteresis  < ± 0.5 %
Linearity Deviation  < ± 0.5 %
Zero-point error < ± 1 %
Repeat Accuracy < ± 0.1 %
Temperature coefficient zero-point <± 0,15% /10K
Temperature coefficient range <± 0,15% /10K

Environmental conditions

Temperature of medium -25 ... 125 °C*
Ambient temperature -25 ... 80 °C
Storage temperature -25 ... 80 °C
EMC DIN EN 61326-2-3
Shock resistance per DIN IEC 68-2-27 30 g / 11 ms
Vibration resistance per DIN IEC 60068-2-6 20 g (10...2000 Hz)

Electrical Data

Supply Voltage 12 ... 28 V DC
Current Consumption (Ub = 24 V) ≤ 30 mA
Number of analog outputs 1
Analog Output 4...20 mA
Signal source Pressure
Current Output Load Resistance < 500 Ohm
Short Circuit Protection yes
Reverse Polarity Protection no
Protection Class III

Mechanical Data

Housing Material Stainless steel, V4A (1.4404 / 316L)
Material in contact with media Stainless steel, V4A (1.4404 / 316L)

Rubber, FKM
Degree of Protection IP67/IP68
Connection Cable, 2-wire, 2 m
Process Connection M5 x 0.8
Seal material Fluororubber, FKM
Bending radius (used in motion) 5 × d
Bending radius (fixed installation) ≥ 3 × d
Drag Chain Suitable yes
Cable Jacket Material PVC
Weight 45 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 3,842.62 a

Output

Analog Output yes

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* Sensors suitable up to temperature of medium of 125 °C. During installation, please ensure that the sensor housing is sufficiently cooled by the surroundings.
** The sensor is not suitable for highly viscous liquids and mixtures containing particles

Connection Diagram

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
Tightening torque = 1 Nm B_SYM_SCHLUESSEL_13.pdf Wrench Size
Initial start-up instructions
Quick-start guide
Declarations of Conformity / Approvals

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.