SG4-00VA000R2 Safety Relay Basic Module

Available from stock
In combination with the safety light curtains SG-I and safety light arrays SB-I, the relay unit allows for the interruption of safety-relevant circuits. Floating safety relays are utilized.

Electrical Data

Supply Voltage 21.6 ... 28.8 V DC
Input wiring 2-channel
Response time (automatic start) 20 ms
Fall time (emergency stop) 8 ms
Temperature Range -20 ... 50 °C
Number of Safety Outputs stop 0 2
Switching current safety output (250 V AC) 3 A

Mechanical Data

Housing Material Plastic, PA
Degree of Protection IP20
Connection Screw-type connection (pluggable)
Clampable Wire Cross-Section 0.25 ... 2.5 mm²
DIN-Rail mounting 35 mm
Weight 210 g

Safety-relevant Data

Safety Category (EN ISO 13849-1), Stop 0 up to 4
Performance Level (EN ISO 13849-1), Stop 0 up to Cat. 4 PL e
Mission Time TM (EN ISO 13849-1) 20 a
Stop Category (EN 60204-1) 0
B10d Switching Cycles (mechanical) 40 000 000
B10d Switching Cycles (60 % load) 400 000
B10d Switching Cycles (100 % load) 200 000

Function

Start, automatically yes
Input signal OSSD yes

Output

NO yes

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Connection Table

B_ANS_TAB_30.pdf

Ctrl. Panel

71 = Channel 1
87 = Channel 2

Dimensioned Picture