Injection Molding Part Detection on a Mill Using a Light Curtain
Challenge:
In plastics processing, defective injection-molded parts are shredded in mills and fed into recycling. To avoid unnecessary running times, the mill should only start when material feed is present. Since the parts fall at different positions within the feed area and the confined installation conditions do not allow for a conventional sensor arrangement, a flexible solution is required for comprehensive detection.
Solution:
Two staggered PEHT light curtain strips jointly monitor the entire inlet area of the mill. As soon as an injection molded part interrupts the light beams, the mill is started. An additional bridge module enables the flexible connection and positioning of the two light grid strips. This allows the sensor arrangement to be optimally adapted to the existing installation conditions and reliably monitors the entire input area.