There is already an innovative successor for the desired product. Click on “Show differences only” to see all improvements at a glance.
Successor product(s)
Electrical Data
Sensor Type
Emitter
Set
Set
Supply Voltage
21.6 ... 26.4 V DC
19.2 ... 28.8 V DC
19.2 ... 28.8 V DC
Current Consumption (Ub = 24 V)
100 mA
≤ 350 mA
≤ 350 mA
Temperature Range
-20 ... 50 °C
-30 ... 55 °C
-30 ... 55 °C
Number of safety outputs (OSSDs)
-
2
2
Function
Scope of functions
Basic function
Muting
Basic function
General product data
Range
0.5...20 m
0.5...50 m
0.5...50 m
Housing
Array
Array
Array
Dimensions
40,2 × 47,1 mm (EI)
40 × 47 mm (EF)
40 × 47 mm (EF)
Special feature
CascadableContactor MonitoringFix BlankingReduced ResolutionRestart InhibitSerial Communication
-
-
Functions
Basic functionBody protectionCascadingContactor monitoringFix blankingRestart inhibitSerial communication
Beam codingBody protectionCascadingContactor monitoringIntegrated indicator lampMuting modeOverrideRestart inhibitSafety operating modeSerial communicationSwitching position indicator
Basic functionBody protectionContactor monitoringRestart inhibitSafety operating modeSerial communication
Interface
-
IO-Link
IO-Link
Mechanical Data
Housing Material
Aluminum, powder-coated
Aluminum, anodised
Aluminum, anodised
Optic Cover
Plastic, PC
Plastic, PC
Plastic, PC
Degree of Protection
IP67
IP65/IP67
IP65/IP67
Connection
M12 × 1; 4-pin
M12 × 1; 8-pin
M12 × 1; 8-pin
Optical Data
Beam Distance
500 mm
500 mm
500 mm
Number of Beams
2
2
2
Light Source
Red Light
Red Light
Red Light
Wavelength
650 nm
630 nm
630 nm
Max. Ambient Light
-
10,000 Lux
10,000 Lux
Safety-relevant Data
ESPE Type (EN 61496)
4
4
4
Performance Level (EN ISO 13849-1)
PL e
Cat. 4 PL e
Cat. 4 PL e