text.skipToContent text.skipToNavigation

SD4RAS02SN89 Safety Switch RFID

仓库中有现货
Separating safety devices can be easily protected up to cat. 4 PL e using these contactless safety switches, even during series connection. Response and risk times remain unchanged at all times. Extensive diagnosis functions boost system availability and make installation and maintenance easier. The locking version can be used as a stop and secures small doors or flaps.

Electrical Data

Sensor Type Switch
Response Time < 100 ms
Risk time < 200 ms
Temperature Range -25 ... 70 °C
Storage temperature -25 ... 85 °C
Safety Output OSSD
Number of safety outputs (OSSDs) 2
PNP Safety Output/Switching Current < 250 mA
Safety Output Voltage Drop < 1 V
Number of Signal Outputs 1
PNP signal output switching current 50 mA
Short Circuit Protection yes
Overload Protection yes
Reverse Polarity Protection yes
Protection Class II

Mechanical Data

Switching Distance 12 mm
Protected Sao switching-off distance 10 mm
Protected Sar switching-off distance 16 mm
Housing Material Plastic
Degree of Protection IP65
IP67
IP69K
Connection Type Plug variant
Connection M12 × 1; 8-pin
Latching Force, typical 18 N
重量 153 g

Safety-relevant Data

Operating principle RFID
Coding Standard
Performance Level (EN ISO 13849-1) 4 PL e
PFHD 2,70 × E-10 1/h
Safety Integrity Level (EN 61508) SIL 3
Safety Integrity Level (EN 62061) SILCL 3
PDDB (EN 60947-5-3) yes

Function

Series Connection yes
Permanent magnet yes

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf

Connection Diagram

Dimensioned Picture

最多可以比较四件产品。