text.skipToContent text.skipToNavigation
  • Scaled switching distance adjuster
  • Energy savings thanks to EcoMode
  • Optimized performance
  • Quick wiring
  • Time-saving installation with fast-clip mounting system

OPT1505 Reflex Sensor with Background Suppression

available from stock
These sensors have been specially designed for use in accumulation roller conveyors. Their compact design allows for installation between rollers below the transport level. High-precision background suppression makes it possible to reliably detect even black objects at up to 900 mm. The scaled switching-distance adjuster assures quick and simple adjustment to the desired distance. Thanks to the innovative fast-clip mounting system and quick wiring, the sensor are installed and ready for use in no time flat.
Optical Data
Range 900 mm
Switching Hysteresis  < 5 %
Light Source Infrared Light
Wavelength 860 nm
Service Life (T = +25 °C) 100,000 h
Risk Group (EN 62471) 1
Max. Ambient Light 90,000 Lux
Opening Angle 3 °
Electrical Data
Supply Voltage 23 ... 27.8 V DC
Current Consumption Sensor (Ub = 24 V) < 16 mA
EcoMode yes
Switching Frequency 100 Hz
Response Time 5 ms
Temperature Drift < 5 %
Temperature Range -40 ... 60 °C
Number of Switching Outputs 1
Switching Output Voltage Drop < 0.9 V
PNP Switching Output/Switching Current 200 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Logic yes
Single Discharge yes
Block Forwarding yes
Solenoid Valve yes
Protection Class III
Mechanical Data
Setting Method Potentiometer
Housing Material Plastic
Degree of Protection IP65
Connection M12 × 1; 4-pin
Cable Length 200 cm
Pneumatic Solenoid Valve Unit
Valve no. K03
Supply Voltage Valve 21.6 ... 26.4 V
Current Consumption Valve 42 mA
Valve temperature range -10 ... 55 °C
Operating Pressure 0 ... 8 bar
Nominal Width 0.9 mm
Nominal flow rate 1 -> 2 22 Nl/min
Nominal flow rate 2 -> 3 25 Nl/min
Supply-Line Connector Pipe 2× 8×1
Working-Line Connector Pipe 4×1
Valve function 3/2-Way
Switching function NO
Output
PNP NC yes
Standards and certificates
B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
Connection Diagram
Switching Distance Deviation
Typical characteristic curve based on white, 90 % remission
Sr = Switching Distance
dSr = Switching Distance Change
black 6 % remission
grey 18 % remission
Ctrl. Panel
30 = Switching Status/Contamination Warning
05 = Switching Distance Adjuster
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode Screw M4 = 0,5 Nm
Complementary Products
  • Adapter OPT70N, OPT70S, OPT70P
  • ZPTX001 Quick Mount
Product Comparison
3/4
4/4
5/4
6/4