text.skipToContent text.skipToNavigation
  • 2 mutually independent switching outputs
  • Wide working range and precise detection thanks to DS technology
  • No interactive influence
  • Intuitive operating concept

P1PY101 Laser Distance Sensor Long-Range

available on request
The sensors function in accordance with the principle of transit time measurement with laser class 1. The wintec with Dynamic Sensitivity technology (DS) enables previously unattainable reception sensitivity even with very weak signals. As a result, the sensors have a large working range of up to 10 m and can reliably detect dark or shiny objects even at extreme angles. wintec also works very reliably in adverse ambient conditions, e.g., caused by ambient light or dirt. Extensive condition monitoring functions additionally enable predictive maintenance and trouble-free operation.
Optical Data
Working Range 0 ... 10,000 mm
Adjustable Range 50 ... 10,000 mm
Reproducibility maximum 3 mm*
Linearity Deviation 10 mm*
Switching Hysteresis  < 15 mm
Light Source Laser (red)
Wavelength 660 nm
Service Life (T = +25 °C) 100,000 h
Laser Class (EN 60825-1) 1
Beam Divergence < 2 mrad
Max. Ambient Light 100,000 Lux
Light Spot Diameter see Table 1
Electrical Data
Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) < 35 mA
Switching Frequency 50 Hz*
Switching Frequency (max.) 250 Hz*
Response Time 15 ms *
Response Time (min.) 4.7 ms *
Temperature Drift < 0.4 mm/K
Temperature Range -40 ... 50 °C
Number of Switching Outputs 2
Switching Output Voltage Drop < 2.5 V
Switching Output/Switching Current 100 mA
Reverse Polarity and Overload Protection yes
Short Circuit Protection yes
Interface IO-Link V1.1
Baud Rate COM3
Protection Class III
FDA Accession Number 2110079-001
Mechanical Data
Setting Method Teach-In
Housing Material Plastic
Optic Cover PMMA
Degree of Protection IP67/IP68
Connection M12 × 1; 4/5-pin
Safety-relevant Data
MTTFd (EN ISO 13849-1) 547.59 a
Output
PNP NO yes
IO-Link yes
Adjustable parameters
Output Error Output
Push-pull
NPN
PNP
Warning output
Circuit NC/NO
NC
NC+NO
NO
Other parameters Off-delay
On-delay
Sensitivity
Filter
Unit of measure
Measuring mode
Emitted light
Sensor localization
Key illumination
Teach mode
All other parameters can be found in the product documentation.
Standards and certificates
B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* Depends on mode, see table 2
Table 1
Working Distance 0 m 5 m 10 m
Light Spot Diameter 5 mm 10 mm 15 mm
Table 2
Connection Diagram
- = supply voltage 0 V
+ = supply voltage +
E/A1 = programmable input/output / IO-Link
E/A2 = programmable input/output
E3 = input
Switching Distance Deviation
Typical characteristic curve based on white, 90 % remission
Sr = Switching Distance
dSr = Switching Distance Change
black 6 % remission
grey 18 % remission
Ctrl. Panel
06 = Teach Button
68 = supply voltage indicator
5a = Switching Status Display, O1
6a = Switching Status Display, O2
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode Screw M4 = 0,5 Nm
Complementary Products
  • IO-Link Master
  • Software
Initial start-up instructions
Operating instructions
Product description file
Product description file
IODD_P1PY101_V1.1.zip
Interface protocol
Interface protocol
Interface_Protocol_IO-Link_Parameter_Process_Data_PxPY10x.pdf
EU Declaration of Conformity
Product certificates
Product certificates
P1PY1_Manufacturer_declaration.pdf
Product Comparison
3/4
4/4
5/4
6/4