ODX402P0099 Fiber-optic amplifier

Available from stock
These sensors are connected to the basic module. wenglor fiber optic cables can be adapted to them. The graphic display assures easy, menu-driven sensor setup. Signal strengths and the switching threshold can be read from the display as numeric values or as a bar graph. Convenient programming and quick diagnosis is possible via the IO-Link interface.

Optical Data

Switching Hysteresis  < 15 %
Light Source Red Light
Wavelength 660 nm
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 10,000 Lux

Electrical Data

Current Consumption (Ub = 24 V) + 10 mA
Response Time  + 70 µs
On-/Off-Delay 0 ... 10,000 ms
Temperature Drift < 10 %
Temperature Range -25 ... 60 °C
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Teach Mode NT, MT, ZT, DT, FT, HT, TP
Protection Class III

Mechanical Data

Setting Method Menu (OLED)
Housing Material Plastic, ABS
Plastic, PC
Degree of Protection IP50
DIN-Rail mounting 35 mm
Weight 37 g

Safety-relevant Data

MTTFd (EN ISO 13849-1) 1,089 a

Output

PNP NO yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit NC
NC/NO
NO

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
Display brightness may decrease with age. This does not result in any impairment of the sensor function.

Ctrl. Panel

60 = display

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")
1 = Transmitter Diode 2 = Receiver Diode