text.skipToContent text.skipToNavigation
  • Compact, laser-welded stainless steel 316L housing
  • Analog output: 4…20 mA
  • Very fast response time of < 1 s
  • Very low weight at 13 g (without cable)
  • Very small format at Ø 14 mm, SW13

FM6P201 Pressure Sensor

available from stock
The weFlux²micro miniature pressure sensor with analog output is distinguished by its space-saving design and low weight. This enables precise pressure measurements in confined installation spaces and on moving plant components such as robot arms. The short response time (<1 ms) allows the sensor to be implemented in quick pressure measurement applications – for example, when monitoring pressure curves in hydraulic systems.
Sensor-specific data
Measuring Range -1 ... 25 bar
Measurement Type relative
Maximum overload pressure 50 bar
Bursting pressure 120 bar
Medium Liquids, gases
Pressure response time (t90) < 1 ms
Measuring error (total)  ± 1 %
Hysteresis  < ± 0.5 %
Linearity Deviation  < ± 0.5 %
Zero-point error < ± 0.5 %
Repeat Accuracy < ± 0.1 %
Temperature coefficient zero-point <± 0,15% /10K
Temperature coefficient range <± 0,15% /10K
Environmental conditions
Temperature of medium -25 ... 125 °C*
Ambient temperature -25 ... 80 °C
Storage temperature -25 ... 80 °C
EMC DIN EN 61326-2-3
Shock resistance per DIN IEC 68-2-27 30 g / 11 ms
Vibration resistance per DIN IEC 60068-2-6 20 g (10...2000 Hz)
Electrical Data
Supply Voltage 9 ... 30 V DC
Current Consumption (Ub = 24 V) ≤ 30 mA
Analog Outputs 1
Analog Output 4...20 mA Press
Current Output Load Resistance < 500 Ohm
Short Circuit Protection yes
Reverse Polarity Protection yes
Protection Class III
Mechanical Data
Sensor element Steel 1.4548
Housing Material 1.4404
Material in contact with media 1.4404; 1.4548; FKM
Degree of Protection IP67/IP68
Connection Cable, 2-wire, 2 m
Process Connection M5 x 0.8
Seal material FKM
Bending radius (used in motion) 5 × d
Bending radius (fixed installation) ≥ 3 × d
Drag Chain Suitable yes
Jacket Material PVC
Safety-relevant Data
MTTFd (EN ISO 13849-1) 3,842.62 a
Output
Analog Output yes
Standards and certificates
B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
* Not UL certified ** Sensors up to 125 °C medium temperature suitable. During installation, please ensure that the sensor housing is sufficiently cooled by the surroundings.