text.skipToContent text.skipToNavigation
  • Up to 12 million measuring points per second
  • Optimized profile quality thanks to HDR function
  • Precise measuring range resolution X (> 2000 measuring points)
  • Increased resistance to extraneous light and high speed

MLWL142 2D/3D Profile Sensor

available on request
2D/3D Profile Sensors project a laser line onto the object to be detected and generate an accurate, linearized height profile with an internal camera which is set up at a triangulation angle. Thanks to its uniform, open interface, the weCat3D series can be incorporated by means of the DLL program library or the GigE Vision standard without an additional control unit. Alternatively, wenglor offers its own software packages for implementing your application.
Optical Data
Working range Z 83 ... 213 mm
Measuring range Z 130 mm
Measuring range X 50 ... 110 mm
Linearity Deviation 32.5 µm
Resolution Z 3.2 ... 14 µm
Resolution X 26 ... 55 µm
Light Source Laser (red)
Wavelength 660 nm
Laser Class (EN 60825-1) 3R
Environmental conditions
Ambient temperature 0 ... 45 °C
Storage temperature -20 ... 70 °C
Max. Ambient Light 5,000 Lux
EMC DIN EN 61000-6-2; 61000-6-4
Electrical Data
Supply Voltage 18 ... 30 V DC
Current Consumption (Ub = 24 V) 300 mA
Measuring Rate 175 ... 6,000 /s
Subsampling 350 ... 6,000 /s
Inputs/Outputs 4
Switching Output Voltage Drop < 1.5 V
Switching Output/Switching Current 100 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Interface Ethernet TCP/IP
Baud Rate 100/1000 Mbit/s
Protection Class III
FDA Accession Number 1710275-000
Mechanical Data
Housing Material Aluminum
Degree of Protection IP67
Connection M12 × 1; 12-pin
Type of Connection Ethernet M12 × 1; 8-pin, X-cod.
Optic Cover Glass
Weight 570 g
General Data
Web server yes
Output
Push-Pull yes
Adjustable parameters
Output Push-pull
NPN
PNP
Circuit NC
NC/NO
NO
All other parameters can be found in the product documentation.
Standards and certificates
B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
Display brightness may decrease with age. This does not result in any impairment of the sensor function.
Connection Diagram
Measuring field X, Z
Z = Working distance
X = Measuring Range
Ctrl. Panel
20 = Enter key
22 = Up key
23 = Down key
60 = display
4a = User LED
68 = supply voltage indicator
78 = Module status
85 = Link/Act LED
Dimensioned Picture
Dimensions specified in mm (1 mm = 0.03937")
Complementary Products
  • Control Unit
  • Switch EHSS001
  • Cooling Unit ZLWK002
  • Protective Screen Retainer ZLWS002
  • Software
Operating instructions
Quick-start guide
General instructions
General instructions
DNNF020.pdf
Software/firmware
Software/firmware
Example_Rockwell_TCP_UDP_uniVision_1.0.0.zip Example_TIA_TCP_UDP_uniVision_1.0.0.zip Example_TwinCAT3_TCP_UDP_uniVision_1.0.0.zip Firmware_weCat3D_1.2.5.zip Firmware_weCat3D_2.0.1.zip SDK_Windows_LabView_weCat3D_1.2.0.zip Software_uniVision_2.4.1.exe weCat3D_GigE_Interface_Windows_X64_2.0.1.zip weCat3D_Obsolet_GigE_Interface_Windows_X64_V1_2_0.zip weCat3D_SDK_Windows_Linux_1_5_0.zip
Interface protocol
Interface protocol
Interface_Protocol_DNNFxxx_LIMA.pdf Interface_Protocol_DNNFxxx_TCP_UDP.pdf Interface_Protocol_MLSL_MLWL.pdf
EU Declaration of Conformity
Product Comparison
3/4
4/4
5/4
6/4