BLN0H1R20 Barcode Line Scanner CCD Array

Available from stock
This scanner is particularly suitable for detecting 1D codes printed or lasered on glossy materials. It works reliably even with small contrast differences and poor code quality. Readable code types: Code39, Full-ASCII-Code39, Interleaved 2 of 5, China Postal Code, Codabar, Code32, MSI Plessy Code, Code11, Industrial 2 of 5, Matrix 2 of 5, Telepen Code, UK Plessy Code, IATA Code, Code93, EAN13, EAN8, UPC-A, UPC-E, Code128, UCC/EAN-128, RSS-14, RSS-Limited

Optical Data

Barcode Density Wide angle
Read Range 20 ... 200 mm
Resolution 0.075 mm
Light Source Red Light
Wavelength 625 nm
Service Life (T = +25 °C) 100,000 h
Max. Ambient Light 70,000 Lux
Opening Angle 65 °
Barcode Printing Contrast > 30 %

Environmental conditions

Temperature Range -20 ... 60 °C
Atmospheric humidity 5...95%, non-condensing

Electrical Data

Supply Voltage 18 ... 30 V DC
Port Type 100BASE-TX
Current Consumption (Ub = 24 V) < 100 mA
Scan Rate 510 scans/sec
Inputs/Outputs 4
Switching Output Voltage Drop < 2.5 V
PNP Switching Output/Switching Current 100 mA
Short Circuit Protection yes
Reverse Polarity Protection yes
Overload Protection yes
Network Possibilities Ethernet
Interface RS-232/Ethernet
Protection Class III

Mechanical Data

Housing Material Aluminum, powder-coated
Optic Cover Plastic, PMMA
Degree of Protection IP67
Connection M12 × 1; 8-pin
Type of Connection Ethernet M12 × 1; 8-pin, X-cod.
Weight 217 g

General Data

Web server yes

Output

Configurable as PNP/NPN/Push-Pull yes
Switchable to NC/NO yes
Ethernet yes
RS-232 Interface yes

Adjustable parameters

Output Push-pull
NPN
PNP
Circuit NC
NC/NO
NO
Other parameters Display unit
On-delay
Output delay
Trigger input
All other parameters can be found in the product documentation.

Standards and certificates

B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf B_SYM_CE_01.pdf
Display brightness may decrease with age. This does not result in any impairment of the sensor function.

Connection Diagram

Scanning Field Diagram

Ctrl. Panel

20 = Enter key
22 = Up key
23 = Down key
60 = display

Dimensioned Picture

Dimensions specified in mm (1 mm = 0.03937")

Complementary Products

  • Fieldbus Gateway ZAGxxxN01, EPGG001
  • Protective Housing ZNNS001, ZNNS002
Operating instructions
Quick-start guide
General instructions
General instructions
BLN_Function_block_Step7.pdf BLN_Function_block_TIA_V13.pdf Change_IP_adress_Windows7-10.pdf
Soft- and Firmware
Soft- and Firmware
Function_Block_STEP7_BLN.zip Function_Block_TIA_BLN.zip
Interface protocol
Interface protocol
Interface_Protocol_BLN.pdf
Declarations of Conformity / Approvals

Product Highlights

This area provides a deeper insight into this product world. All information about new product series as well as tutorials, templates and much more are combined here and are clearly prepared – tangible, understandable and traceable. Everything at a glance.
Product Comparison