Choose a language
wenglor web page
Reflex Sensor for Measuring Tasks
HT60MGV80
Optical Data
300...600 mm
450 mm
300 mm
see Table 1
1 %
20 mm
Red Light
660 nm
100000 h
10000 Lux
see Table 1
Electrical Data
18...30 V DC
< 50 mA
50 Hz
10 ms
100 µm/K
-10...60 °C
< 2,5 V
200 mA
< 2,5 V
200 mA
0...10 V
500 µA
yes
yes
yes
III
Mechanical Data
Plastic
IP67
M12 × 1; 8-pin
Output
yes
yes
yes
Table 1
Working Distance 300 mm 450 mm 600 mm
Light Spot Diameter 10 mm 15 mm 20 mm
Resolution 0,3 mm 2 mm 5 mm
Connection Diagram
Error of Measurement
Typical characteristic curve based on Kodak white (90 % remission)
  • Sr = Switching Distance
  • dSr = Switching Distance Change
black 6 % remission
grey 18 % remission
Ctrl.Panel
  • 01 = Switching Status Indicator
  • 13 = Upper Potentiometer
  • 14 = Lower Potentiometer
  • 33 = Analog Voltage Output-/Error Warning
Dimensioned Picture
All dimensions in mm (1 mm = 0.03937 Inch)
  • 1 = Receiver Diode
  • 2 = Transmitter Diode
  • 3 = Receiver Diode
Complementary Products
Analog Evaluation Unit AW02
© 2013  wenglor sensoric gmbh  |  Impressum  |  Sitemap